Version 6.01a1 and above
For older versions and revisions go to our archive |
|
JPA Designer has passed the latest round of BRE testing. To indicate this the version number has been changed from 6.03b1 to 6.04a1.
Build 003 was the first public build of 6.04a1: builds 001 and 002 were internal development builds. |
|
19 November 2019: Version 6.04a1 Builds 030 & 031 - main changes |
• Update to allow '4' status flag (methodology under review) to be shown when selecting certain systems from the pcdf2012 database. |
|
10 October 2019: Version 6.04a1 Build 029 - main changes |
• Fixed small glitch in Loft Hatch to show correct figures, not 0.00. |
|
27 September 2019: Version 6.04a1 Builds 025 - 28 - main changes |
• Addition of bespoke U-value Tapered Layer import for some users. |
|
11 February 2019: Version 6.04a1 Builds 021 - 24 - main changes |
• Minor changes to IES 3D import |
|
11 June 2018: Version 6.04a1 Build 019 & 20 - main changes |
• To link to new on-line licensing servers. IMPORTANT UPDATE |
|
29 March 2018: Version 6.04a1 Build 018 - main changes |
• Minor bug fix to printing batch SAP reports. |
|
20 February 2018: Version 6.04a1 Build 017 - main changes |
• Minor bug fix to UPRN lookup. |
|
03 February 2018: Version 6.04a1 Build 016 - main changes |
• Minor bug fixes to RH values. |
|
30 January 2018: Version 6.04a1 Build 014 - main changes |
• Fixed an issue where the calculations get lower even though the P/A is higher. |
|
07 December 2017: Version 6.04a1 Build 013 - main changes |
• Fixed an issue with the DHW consumption. |
|
03 November 2017: Version 6.04a1 Builds 010, 011 & 12 - main changes |
• Updates to Uvalue materials database. |
|
08 April 2017: Version 6.04a1 Builds 008 and 009 - main changes |
• Minor bug fixes to printing options. |
|
11 April 2017: Version 6.04a1 Build 007 - main changes |
- Condensation risk analysis:
• New region of Europe and climate data for seven weather stations in Turkey.
- SAP 2012:
• Draft implementation of HQM data export. |
|
08 April 2017: Version 6.04a1 Build 006 - main changes |
• Internal development build, not released. |
|
21 February 2017: Version 6.04a1 Build 005 - main changes |
- U-Value:
• Resolved issue in which calculation of the effect of horizontal edge insulation on solid floors was using the incorrect surface resistance.
- SAP 2012:
• The TFEE, DFEE and TER are now included in the data set exported to Excel.
• PDFs of the multiple dwellings report now includes all dwellings when the list exceeds one page.
• An incorrect error message displayed when an exhaust air heat pump was selected in the Ventilation and primary heating tabs has been removed. |
|
26 January 2017: Version 6.04a1 Build 004 - main changes |
- U-Value:
• Improved presentation of correction factors in calculation reports.
- VE import:
• Opening orientation is now correctly imported. |
|
06 December 2016: Version 6.04a1 Build 003 - main changes |
- SAP 2012:
• High heat retention storage heaters are now correctly recognised as an item selected from the database, allowing calculations to be completed.
- U-Value:
• Multiple standard notes can now be added to calculation reports.
• Long layer names should no longer cause report creation to fail.
• Inserting a well-vented cavity from the database will now result in the external surface resistance being set to match the internal surface resistance.
• Pagination of variable layer calculations corrected. |
|
01 December 2016: Version 6.04a1 Builds 001 & 002 - main changes |
• Internal development build, not released. |
|
03 November 2016: Version 6.03b1 Build 019 - main changes |
- SAP 2012:
• Removed incompatible SAP 2009 junction codes (that is, those with a hyphen in the code, e.g. E-1) from the Calculate Htb dialogue.
• Corrected issue where the on-screen compliance check could show a fail for uninsulated primary pipework, even though the pipework is marked as insulated.
• Printing of SAP reports for several dwellings at once now works as intended: previously it would print the results of the first calculation several times.
• Resolved issue where using JPA Designer on a PC with Italian language and regional settings prevented any data being entered in the Calculate Htb dialogue.
- U-Value:
• You can now save user-defined notes in the Project notes tab, reducing retyping of common phrases.
- Condensation risk analysis:
• User-defined pre-sets of environmental conditions now save correctly.
- R-values:
• R-value reports for New Zealand and Australia now show out and in R-values correctly. |
|
13 October 2016: Version 6.03b1 Build 018 - main changes |
- SAP 2012:
• Resolves an issue where special fuel details entered in releases before 6.02a1 build 011 would be lost when the calculation was opened in subsequent versions.
- U-Value:
• Resolves issue where fixing corrections for layers in basement walls were not included in the final U-value. |
|
13 September 2016: Version 6.03b1 Build 017 - main changes |
- General:
• Added option to import SAP calculation from another project.
- SAP 2012:
• Add ‘Clear’ button to remove a heating controller which has been selected from the PCDF (the database).
- U-Value:
• Added a ‘Clear’ button to the Tapered layer dialogue which will delete all roof sections in one action.
- Condensation Risk:
• It is no longer possible to carry out condensation risk analysis on ground floors and basement floors and walls. The methods used for U-value calculations on those elements are incompatible with the method of condensation risk analysis. See Technical note 2016/1 for guidance. |
|
10 August 2016: Version 6.03b1 Build 016 - main changes |
- General:
• A new ‘copy from clipboard’ button has been added to the address details dialogues. This makes it easier for users to import details from a CRM system. The CRM software must export the data to the clipboard in the following format: "Name/Company name", "Address Line 2", "Address Line 3","Address Line 4", "Address Line 5", "Post Code".
- SAP 2012:
• Ability to batch PDF all the SAPs selected in the project manager added.
• Excel export now includes SAP worksheet box numbers in the format, making it easier to identify and extract information. |
|
20 July 2016: Version 6.03b1 Build 014 - main changes |
- SAP 2012:
• The program now displays a warning if a heat pump which does not produce hot water is specified to do so.
• Issue resolved whereby copying building services data to all dwellings in a project deleted storey data for dwellings on the fourth floor and above.
• Multiple dwellings calculation for Scotland no longer displays DFEE/TFEE on screen or reports.
• The range of data included in the Excel export from SAP has been expanded and now includes energy demand and energy use results. This makes it easier to summarise results for large projects.
- U-value:
• Generic blockwork in the database now has the bridge thickeness set to ‘follows material thickness’ by default. |
|
12 July 2016: Version 6.03b1 Builds 012 & 013 - main changes |
- SAP 2012:
• Resolved error that when a SAP 2012 calculation was duplicated in the Project Manager window any second main heating was not carried into the new calculation.
• Resolved error that when an XML file containing a SAP calculation was imported into JPA Designer any solar thermal settings were not imported correctly.
• SAP worksheets now show version 6.03 on bottom of printout. |
|
01 July 2016: Version 6.03b1 Build 011 - main changes |
• Internal development build, not released. |
|
21 June 2016: Version 6.03b1 Builds 009 & 010 - main changes |
- U-value:
• Updates to the materials database and general bug fixes. |
|
13 June 2016: Version 6.03b1 Build 008 - main changes |
- General:
• Resolves ‘error 5’ warning on closing JPA Designer. This was a result of changes to the user-defined environmental conditions pre-sets.
- U-value:
• Twin-skin metal cladding calculation modified, with data entry field for rail depth, bringing it fully into line with SCI P312 calculation.
- SAP:
• MicroCHP boilers now show correctly in the BRE Boiler Database dialogue.
• Resolves issue with selection of boiler with intergral FGHR in SAP 2009.
• There is now a 'clear' button for removing a weather or load compensator which has been selected from the Product Characteristics Data File (the 'boiler database’). |
|
01 June 2016: Version 6.03b1 Build 007 - main changes |
- SAP:
• Minor amends to EPC lodgement to accommodate dwellings in the sixth storey or higher. |
|
19 May 2016: Version 6.03b1 Build 006 - main changes |
- U-value:
• The changes in the Environmental Conditions dialogue affected data entry for the pre-2003 method. That has now been restored.
• It is now possible to view and use the generic product data for all regions. In the Options dialogue (Project Manager window) the Other tab has a new tick box: Show generic product data for all regions. This option is intended for users carrying out condensation risk analysis in Australia and New Zealand, enabling the use of UK generic data in cases where local generic product data is incomplete or unavailable.
- SAP 2012:
• It is now possible to set up a hybrid ASHP in SAP 2012 with the ASHP as the first main heat source providing all the space heating requirement, and the gas boiler as the second main heat source providing none of the space heating, but all of the hot water. |
|
19 April 2016: Version 6.03b1 Build 005 - main changes |
• Internal development build, not released. |
|
19 April 2016: Version 6.03b1 Build 004 - main changes |
- U-value:
• The Environmental conditions dialogue has been re-designed, making data selection more logical.
• There is now a dialogue for creating and editing user pre-sets of internal and external climate conditions. This is described in more detail in Technical Note 2016-03.
• The mechanical fasteners description now appears correctly on calculations featuring warm, cold or hybrid steel frame constructions.
- SAP 2012:
• MEV /MVHR selection is not re-set or blanked when then database window is opened again. |
|
29 March 2016: Version 6.03b1 Build 003 - main changes |
- SAP 2012:
• Scottish EPC submission now includes correct status for pressure testing of dwelling. |
|
22 March 2016: Version 6.03b1 Build 002 - main changes |
- U-value:
• Corrected calculation of kappa values in ground floors and basements, so calculation considers layers in the correct order. Previously it was going from outside to inside, instead of inside to outside.
• Corrected the treatment of well-vented cavities in ground floors and basements: now layers to the outside of the cavity are set to zero resistance.
• Notes to a calculation will now appear on reports even if there is a variable layer in the calculation. |
|
21 March 2016: Version 6.03b1 Build 001 - main changes |
- SAP 2012:
• EPC lodgements in Scotland are now performed using SAP 2012 not SAP 2009. Users should select v17 EPC, not V15.
• Resolves an issue with the Calculate Htb dialogue. Previously, deleting a junction resulted in the heat loss for each junction not being displayed. |
|
05 March 2016: Version 6.03a1 Build 026 - main changes |
- U-value:
• Fixes a save issue when editing a material from the database. |
|
22 February 2016: Version 6.03a1 Build 026 - main changes |
- U-value:
• Corrected values for loft space resistance in the BR 443 cold pitched roof calculation.
- SAP 2012:
• When duplicating a SAP calculation the client email and phone number are now preserved along with the address. |
|
15 February 2016: Version 6.03a1 Build 024 - main changes |
- U-value:
• Resolves an issue where changing a layer thickness in a U-value calculation linked to a SAP calculation produced an access error. |
|
12 February 2016: Version 6.03a1 Build 023 - main changes |
- SAP 2012:
• Resolves an error with incorrect order of items in the lodgement XML for waste water heat recovery systems. |
|
05 February 2016: Version 6.03a1 Build 022 - main changes |
- U-value:
• Resolves issue with the BR 443 roof calculation. Selecting the roof construction now inserts the correct resistance (as BS EN ISO 6946:2007 table 3). |
|
26 January 2016: Version 6.03a1 Build 021 - main changes |
- SAP 2012:
• It is now possible to specify a district heating scheme from the PDCF. Set the heating Group to Community Heating Scheme then click ‘Select network from database’. Currently the only scheme in the PCDF is the Lerwick network. |
|
21 January 2016: Version 6.03a1 Build 020 - main changes |
- SAP 2012 and 2009:
• An issue preventing the creation of a PDF of the Htb report (thermal bridging) has been resolved. |
|
18 January 2016: Version 6.03a1 Build 019 - main changes |
- U-value:
• The row shading on the tables in U-value reports interfered with the use of watermark images. Row shading is now controlled by an option on the Other tab of the Options dialogue. To show shading tick Print U-value table row shading. |
|
07 January 2016: Version 6.03a1 Build 018 - main changes |
- SAP:
• SAP location data, for region and country, is taken from the PCDF based on the post code. For a few post code areas this results in the country setting being wrong. To allow users to set the correct country there is a new ‘relax country check’ box on the SAP Project Information dialogue.
- U-value:
• Adjustment to report layout to prevent blank pages appearing after the condensation table.
• Value of alpha used in twin-skin metal roofs now set to 1.6 by default.
• Element descriptions on reports now correctly follow those set in the U-value Construction dialogue.
- VE import:
• The VE import has been revised and now includes thermal mass data for internal and external elements. |
|
11 December 2015: Version 6.03a1 Build 017 - main changes |
- U-value:
• Resolves issues with the revised roof elements introduced in build 013.
• Value of alpha used in twin-skin metal roofs now set to 1.6 by default. |
|
26 November 2015: Version 6.03a1 Build 016 - main changes |
- U-value:
• Resolved an issue with the correction factor for rainscreen cladding fixing rails. |
|
20 November 2015: Version 6.03a1 Build 015 - main changes |
- U-value:
• Resolved an issue printing the condensation risk graph, either to a real printer or to a software printer (e.g. to create a PDF).
• The rainwater cooling correction factor for inverted flat roofs is now shown at the bottom of the first page of U-value reports together with the other factors. |
|
16 November 2015: Version 6.03a1 Build 014 - main changes |
- General:
• The program can now handle up to twenty different identities.
• Address details associated with identities can be copied and pasted to and from the
clipboard, making it easer to maintain consistency between users.
- SAP 2012:
• Scottish TER calculation for biomass no longer includes PV, bringing it into line with Section 6.
• Energy demand calculation: the water heating energy demand is now correctly calculated for heat pumps/microCHP which have hot water provided by immersion heaters in summer.
• Filtering of the PCDF boiler list by efficiency and mounting position working again.
• ‘Uninsulated primary pipework’ no longer shows on the compliance checklist as ‘Primary pipework insulated: yes’.
- U-value:
• Details of bracket systems now appear correctly on the U-value Construction dialogue.
• Inverted roof rainwater cooling correction details now placed under the U-value table on reports.
- Condensation risk:
• Lines on the dewpoint graph were not appearing on printed reports (including those produced by ‘software printers’ creating PDFs), but were appearing on PDFs created
directly from JPA Designer. Lines now appear on all reports. |
|
06 November 2015: Version 6.03a1 Build 013 - main changes |
- U-value:
• Two new pitched roof element types, improving compatibility with BR 443.
Existing roof types still exist, but are labelled as legacy. |
|
27 October 2015: Version 6.03a1 Builds 011 & 012 - main changes |
• Minor EPC lodgement changes affecting ecmk users. |
|
27 October 2015: Version 6.03a1 Build 010 - main changes |
- General:
• The check for updates system now compares the date and time stamp of the running version
of the program with that of the installer on the web site. It will notify of the need for updates
if it finds the installed version is more than a day older than the latest installer.
- SAP 2012:
• In Scotland the FEE test was appearing on the compliance status area (bottom right on
the SAP window) when in fact it is not relevant for Scotland. This no longer appears.
- U-value:
• It now possible to have two separate sets of brackets or rails for rainscreen cladding.
• Extra ‘ghost’ header which appears on the thermal mass report when it is printed on
its own (i.e. no U-value report) has been removed.
- Condensation risk:
• Layers outside a well vented cavity which have vapour resistance set to zero because of
the cavity will no longer trigger an error because of that. |
|
21 October 2015: Version 6.03a1 Build 009 - main changes |
- U-value:
• Cladding brackets can also be applied to floors other than ground floors to allow for
soffit insulation and cladding systems.
• Fixed error on the selection of floor perimeter insulation from the database. |
|
13 October 2015: Version 6.03a1 Builds 005 to 008 - main changes |
- U-value:
• Calculations can now have multiple corrections for mechanical fasteners, which can now
be applied in the Edit Material dialogue.
• Edit Material dialogue has been revised to give more space for the corrections.
It now has three tabs: a General tab for the material data, a Thermal Bridging tab and
a Correction factors tab. |
|
02 October 2015: Version 6.03a1 Build 004 - main changes |
• Consolidates changes in Build 003. |
|
01 October 2015: Version 6.03a1 Builds 002 & 003 - main changes |
- SAP 2012:
• Resolves problem caused by duplication in the 2005 SAP database.
• IES VE import now based on a new XML format file generated by VE.
- SAP 2009:
• TFEE and DFEE figures no longer appear on compliance checklist.
They had appeared as a result of the SAP 2012 changes.
- U-value:
• Introduced a revised materials database which only includes materials from approved
sources (ISO 10456, BS 5250, CIBSE guide A, BR 443). This will assist in providing
traceable data in calculations.
• Resolved issue with reversal of proportion bridged and thermal conductivity on user
created bridging defaults.
• Corrections for wind posts added.
• Element selection in Edit Construction dialogue now by dropdown list, not radio buttons. |
|
17 June 2015: Version 6.03a1 Build 001 - main changes |
- SAP 2012:
• Approval for section 6 2015 for Scotland.
• Calculation of junction lengths for openings now allows for consolidation of sill, jamb
and lintel lengths.
• Openings tab modified to show details of more windows at once.
• A new check box on the preview screen will export the current worksheet to Excel.
• Preflight checks for EPC lodgements now include check of junction references.
- U-value:
• Corrects a problem with print and PDF creation for reports with U-value and
condensation outputs.
• There is now an option in the Options dialogue to supress the opening of the file
manager window after printing to PDF. |
|
10 June 2015: Version 6.02a1 Builds 019, 20 & 021 - main changes |
• Internal development builds associated with SAP approval for Scotland. |
|
14 May 2015: Version 6.02a1 Build 018 - main changes |
- SAP 2012:
• Corrects issue with selecting high heat retention storage heaters from the PCDF.
- U-value:
• Updates calculation standard for condensation risk analysis to BS 5250:2011.
• Corrects an issue with user defined mechanical fasteners. |
|
12 May 2015: Version 6.02a1 Builds 016 & 017 - main changes |
• Internal development releases. |
|
08 May 2015: Version 6.02a1 Build 015 - main changes |
- SAP 2012:
• Resolved an issue with selection of oil boilers.
- U-value:
• Resolved an error with saving details of thermal bridge default sets created by
program users. |
|
07 May 2015: Version 6.02a1 Build 014 - main changes |
• Internal development release. |
|
05 May 2015: Version 6.02a1 Build 013 - main changes |
- General:
• There is a new option to omit creation date and file name on reports.
- SAP 2012:
• Resolves an issue with TER calculations with community heating in Scottish SAP 2009
caclulations caused by changes to the SAP 2012 for Scotland.
• Users can now setup a number of default values for SAP calculations using the new
Default tab in the Program Options dialogue. There are defaults for terrain, overshading
of windows and solar panels, and window opening for overheating.
• It is now possible to delete multiple openings simultaneously.
- U-value:
• The options in the U-value construction dialogue have changed to accommodate additional
correction factors for windposts and loft hatches from BR 443. The Element type selection is
now from a dropdown list rather than the former radio buttons.
• It is now possible to add to the set of standard thermal bridges using the New and Edit
buttons in the Edit material dialogue.
• The print options for U-value calculations have been revised so it is now possible to
produce U-value and condensation risk reports together.
• Printing issue on bridge details resolved (incorrect on print out but OK in the calculation). |
|
10 April 2015: Version 6.02a1 Build 012 - main changes |
• Internal development release. |
|
04 March 2015: Version 6.02a1 Build 011 - main changes |
- SAP 2012:
• Eliminated bug which prevented completion of calculation if the water heating from a
second main system was changed to the primary main system and the second system deleted.
- U-value:
• Minor updates to the materials database for Australia.
• Extensive revisions to suspended ground floor U-value calculations and report formats
(see technical note).
• Resolves problems with calculation results which occurred if a bridged cavity was
converted to a well-ventilated cavity. |
|
20 February 2015: Version 6.02a1 Build 010 - main changes |
• Internal development release. |
|
22 January 2015: Version 6.02a1 Build 009 - main changes |
- SAP 2012:
• Fixed error on selection of condensing gas warm-air system from PCDF.
• Fixed TFEE/DFREE descriptions on compliance checklist. |
|
24 December 2014: Version 6.02a1 Build 008 - main changes |
- SAP 2012:
• Community heating scheme hot water only options now showing properly.
• Correction to SAP 2012 Scotland TER calculation for heat pumps. |
|
12 December 2014: Version 6.02a1 Build 007 - main changes |
- Project:
• A new button in the Project Address dialogue will pass down the project address details to
all the calculations in a project.
- Uvalue:
• A new option to create PDFs of all U-value calculations in a project has been added to the
Project Manager File menu.
• The printing of the total construction thickness on a U-value report can be turned on an off
by a new control on the Options dialogue Other tab.
• A watermark can be added to reports produced by the U-value module. The default text,
angle and point size can be specified in the Options menu, while the inclusion of the
watermark is specified in the Sections to print dialogue.
• A new tab in the U-value construction dialogue allows for notes to be added to the report of
a U-value calculation. The notes are printed after the construction thickness.
- SAP:
• The VE import has been updated to allow a choice between creating a SAP 2009 or
SAP 2012 calculation.
• Issue with the identification of openings has been resolved.
• The VE import now includes options for consolidating elements of the same type in the
VE model into single elements in JPA Designer. |
|
11 December 2014: Version 6.02a1 Build 006 - main changes |
• Internal development release.
|
|
10 December 2014: Version 6.02a1 Build 005 - main changes |
- Uvalue:
• Revised material database for Australia added. |
|
27 November 2014: Version 6.02a1 Build 003 & 004 - main changes |
• Internal development releases.
|
|
20 November 2014: Version 6.02a1 Build 002 - main changes |
- SAP 2012:
• Draft SAP 2012 calculations now available for Scotland section 6 2015.
Further information on SAP 2012 for Scotland is available here:
http://forum.techlit.co.uk/viewtopic.php?f=9&t=259 |
|
14 November 2014: Version 6.02a1 Build 001 - main changes |
- SAP 2012:
• SAP 2012 module now approved for use with Part L 2014 for Wales.
- U-Value:
• Layers in the variable layer pane can now be re-ordered by dragging on the layer number,
in the same way as layers in the main pane.
• The tapered layer page in the U-value calculation report now shows U-values and areas for
all tapers in a series of tables.
• Standard references for basement wall and floor, and ground floor U-values have been updated.
• Total thickness of construction not shown for constructions containing variable layers.
|
|
24 October 2014: Version 6.01a1 Build 021 - main changes |
- SAP 2012:
• Manufacturer's efficiency data is now permitted for solid fuel appliances in 'as-built'
calculations for new dwellings.
- SAP 2009:
• Resolves an issue with assessor's registration status in EPC lodgements for Scotland.
|
|
23 October 2014: Version 6.01a1 Build 020 - main changes |
- SAP:
• EPC lodgement: New controls added for editing assessor information.
|
|
16 October 2014: Version 6.01a1 Build 019 - main changes |
- SAP 2012:
• The CSH improvement levels for Ene 1 have been reset to the values in the 2014 revision of CSH.
• Imports from VE more reliable on storey location for rooms and party floors.
• Window U-values now imported from VE.
• An issue resolved where blank junctions which had been removed by the use of the ‘Flush’
button would regenerate when the calculation was opened again.
- SAP 2009:
• Scottish EPC lodgements through ecmk are now possible.
• An issue with certain junction types (E19 or higher, P6 or higher and R1 or higher) which could
prevent Scottish lodgements has been resolved. A pre-flight check now warns if such junctions
are present. Those junctions are also no longer available in SAP 2009.
|
|
14 October 2014: Version 6.01a1 Build 018 - main changes |
- U-value/R-value:
• The product database for Australia has been revised to incorporate vapour resistivity and
resistance data for generic materials.
• The tapered layer report page shows more data for each taper.
|
|
10 October 2014: Version 6.01a1 Build 017 - main changes |
- SAP 2012:
• Multiple dwellings calculations are now available for SAP 2012. They show average TER/DER and
average DFEE/TFEE.
• An issue with the Code for Sustainable Homes report for dwellings with CHP as now been resolved.
• Data entry on thermal bridging has been amended to limit the use of user-defined y-values to
SAP 9.81 or 9.90 which are being upgraded to SAP 9.92 in order to lodge EPCs. User-defined
y-values are not acceptable for compliance with Part L 2013 (England) or Part L 2014 (Wales):
see Technical note 2014/03 for a more detailed explanation.
• Conversion of SAP 2009 to SAP 2012 no longer gives range check error if there is a heat pump
in the original dwelling. Users will still have to reset heat pump data because of incompatibilities
between SAP 2009 and SAP 2012 data.
• Input data worksheet now shows Htb not Hbt.
- SAP 2005 (9.81):
• Dwellings in Scotland with an assumed pressure test value of 10.00 will now take their status
(as built or as designed) from the Project Information dialogue.
- VE Import:
• There is now a choice to import either to SAP 2012 or to SAP 2009, to address different
requirements across England, Wales, Scotland and Northern Ireland.
- U-value:
• The U-value report now shows units for point thermal transmittance as W/K instead of W/mK.
• The U-value report now shows the total thickness of the construction. This is an optional feature.
• The maximum number of blocks in a tapered layer is now 200.
• Thermal bridge proportions can now be set using defaults or direct proportions.
See Technical note 2014/03 for more details.
|
|
03 October 2014: Version 6.01a1 Build 015 & 16 - main changes |
- • Internal development releases.
|
|
18 September 2014: Version 6.01a1 Build 014 - main changes |
- SAP 2012 & U-values:
• Minor bug fixes. |
|
12 September 2014: Version 6.01a1 Build 013 - main changes |
- SAP 2012:
• Fixes an issue with the TFEE where the figure on the worksheet and screen are different.
- U-values:
• Project information window no longer requires a location postcode to proceed.
|
|
10 September 2014: Version 6.01a1 Build 012 - main changes |
- SAP 2012:
• Fixes heating / space heating glitch which caused a ['$' in not a valid integer value] error.
|
|
09 September 2014: Version 6.01a1 Build 011 - main changes |
- SAP 2012:
• Party elements added to the IES import.
|
|
09 September 2014: Version 6.01a1 Build 010 - main changes |
- U-values:
• Fixed issue where selecting thermal mass output on the print dialogue along with a
condensation prediction, it prints the thermal mass data across all of the graphs.
|
|
03 September 2014: Version 6.01a1 Build 009 - main changes |
- SAP 2012:
• No longer possible to set numbers of showers/baths for WWHRS to negative numbers.
• Lodgement issue with FGHRS resolved.
• New facility in Project Manager Edit menu to convert SAP 9.92 calculations to SAP 9.90.
• New Flush button in the Calculate Htb dialogue. Clicking the button removes entries
for any junctions with zero length, i.e. redundant junctions.
|
|
31 July 2014: Version 6.01a1 Build 005 - main changes |
- SAP 2012:
• Restriction on using solid fuel boilers with underfloor heating has been lifted.
The calculation now uses a responsiveness of 0.25 under concrete and 0.75 under screed.
• Import from IES VE software now uses VE 2014 and goes to SAP 2012.
• CSH improvement on ENE 7 will now show correctly. Previously it was occasionally missing.
- SAP 2009:
• The SAP 2009 compliance report no longer includes items from the SAP 2012 report that
were inadvertantly included.
- U-values:
• The product database no longer scrolls back to the category list once a product has been selected.
• Resolved issue where bridging in a layer beyond a well-vented cavity was causing the
resistance the layer to be included in the U-value calculation.
|
|
15 July 2014: Version 6.01a1 Build 004 - main changes |
- SAP 2012:
• An oversized heat pump (that is, one where the PSR of the dwelling is larger than the final
PSR in the PCDF) can now be used. The program interpolates an efficiency following the
method in SAP 2102 appendix N2.
- U-values:
• The loft space in the pitched roof with horizontal ceiling element is now heat in/heat out
for Australia.
- Psi-value assistant:
• Data from linked U-value calculations are read to three decimal places.
|
|
11 July 2014: Version 6.01a1 Build 003 - main changes |
- U-values:
• Fixes a minor bug with the Australian database.
|
|
11 July 2014: Version 6.01a1 Build 002 - main changes |
- General:
• A new splash screen on launch showing options for creating new calculations or
opening existing ones.
- SAP 2012:
• Range check errors generated by using heat pumps from the PCDF have been resolved.
• The benefit of discounted negative emissions associated with biofuel CHP in the zero
carbon homes calculationis now correctly added at box ZC5.
• There is a new selection dialogue for Ru values for elements adjoining unheated spaces:
manual entry of Ru values is still permitted.
• Solar thermal: identification letters corresponding to the performance standards have been
added to text by input boxes, making it easier to correlate data entry with manufacturer’s
data sheets.
- U-values:
• There is now a separate database for products for U-value calculations in Australia.
• For Australia the element type ‘pitched roof horizontal ceiling’ does not have an automatic
loft space and does not adjust for layers on the slope.
• The point thermal transmittance for mechanical fasteners now shows correctly on the first
page of the U-value report.
|
|
02 July 2014: Version 6.01a1 Build 001 - main changes |
- SAP:
• Minor changes to SAP 9.92 module as part of the approval process.
|
|